Taylor Power® TD55 Details
Purpose Built Standby-Diesel Generators

Capacity:

Rated: 55 kW
Category: Stationary
Sub Group: Standby-Diesel

Engine:

Make: Perkins
Model: 1104D-44TG1
Fuel Type: Diesel

Alternator:

Please refer to spec sheet for your particular model

Unit Features:

  • Heavy Duty Steel Base
  • Vibration Isolators
  • Oil Drain Valve with Extension
  • Battery Rack & Cables
  • High Ambient Unit Mounted Radiator
  • Battery Charging Alternator
  • Factory Powder Coating
  • Factory Test
  • Owner’s Manual

Description:

Taylor Power standby diesel generators have been ETL Certified to UL2200. Depending upon your specific requirements, Taylor Power provides standby generators ranging from 9kW to 2000kW. The TD55 is rated at 55kW and has many optional features to meet the unique needs of the individual customers. For more information on this generator, please refer to our specification sheet.

Output Power Options:

Diesel OUTPUT POWER OPTIONS:

Output Power Options 125°C RISE STANDBY RATING 105°C RISE CONTINUOUS RATING sKVA
Make Voltage Alternator Phase Hertz kW/kVA Amps kW/kVA Amps 30% Voltage Dip
Marathon 600 361PSL1633 3 60 55/69 66 50/63 60 189
Marathon 277/480 361CSL1601 3 60 55/69 83 50/63 75 189
Marathon 120/208 361CSL1601 3 60 55/69 191 50/63 174 142
Marathon 120/240 361CSL1601 3 60 55/69 166 50/63 151 142
Marathon 120/240 361CSL1601 1 60 45/45 188 37/37 154 63
Marathon 120/240 361CSL1613 1 60 55/55 229 50/50 208 128
Marathon 277/480 362CSL1604 3 60 58/73 87 53/66 80 317
Marathon 120/208 362CSL1604 3 60 58/73 201 53/66 184 238
Marathon 120/240 362CSL1604 3 60 58/73 175 53/66 160 238
Marathon 120/240 362CSL1604 1 60 52/52 217 53/53 221 128
Stamford 600 UCI224E17 3 60 55/69 66 50/63 60 225
Stamford 277/480 UCI224E311 3 60 55/69 83 50/63 75 210
Stamford 120/208 UCI224E311 3 60 54/68 188 50/63 174 150
Stamford 120/240 UCI224E311 3 60 55/69 166 50/63 151 150
Stamford 120/240 UCI224E311 1 60 45/45 188 42/42 175 108