Taylor Power® TD600 Details
Purpose Built Standby-Diesel Generators

Capacity:

Rated: 600 kW
Category: Stationary
Sub Group: Standby-Diesel

Engine:

Make: Perkins
Model: 2806C-E18TAG3
Fuel Type: Diesel

Alternator:

Please refer to spec sheet for your particular model

Unit Features:

  • Heavy Duty Steel Base
  • Vibration Isolators
  • Oil Drain Valve with Extension
  • Battery Rack & Cables
  • High Ambient Unit Mounted Radiator
  • Battery Charging Alternator
  • Factory Powder Coating
  • Factory Test
  • Owner's Manual

Description:

Taylor Power standby diesel generators have been ETL Certified to UL2200. Depending upon your specific requirements, Taylor Power provides standby generators ranging from 9kW to 2000kW. The TD600 is rated at 600kW and has many optional features to meet the unique needs of the individual customers. For more information on this generator, please refer to our specification sheet.

Output Power Options:

Diesel OUTPUT POWER OPTIONS:

Output Power Options 125°C RISE STANDBY RATING 105°C RISE CONTINUOUS RATING sKVA
Make Voltage Alternator Phase Hertz kW/kVA Amps kW/kVA Amps 30% Voltage Dip
Marathon 600 572RSS4272 3 60 600/750 723 560/700 674 1440
Marathon 277/480 573RSL4033 3 60 600/750 903 560/700 843 1750
Marathon 120/208 573RSL4033 3 60 600/750 2084 560/700 1945 1210
Marathon 120/240 573RSL4033 3 60 600/750 1806 560/700 1686 1210
Marathon 120/240 573RSL4033 1 60 385/385 1604 374/374 1558 545
Marathon 277/480 573RSL4035 3 60 610/763 918 567/709 854 2135
Marathon 120/208 573RSL4035 3 60 610/763 2119 567/709 1970 1510
Marathon 120/240 573RSL4035 3 60 610/763 1836 567/709 1707 1510
Marathon 120/240 573RSL4035 1 60 413/413 1721 391/391 1629 660
Stamford 600 HCI534F17 3 60 550/688 662 505/631 608 2140
Stamford 277/480 HCI534F311 3 60 600/750 903 560/700 843 2300
Stamford 120/208 HCI534F311 3 60 590/738 2050 550/688 1911 1775
Stamford 120/240 HCI534F311 3 60 590/738 1776 550/688 1656 1775
Stamford 120/240 HCI534F311 1 60 295/295 1229 275/275 1146 1180