Taylor Power® TG400 Details
Purpose Built Standby-NG/LP Generators

Capacity:

Rated: 400 kW
Category: Stationary
Sub Group: Standby-NG/LP

Engine:

Make: Doosan
Model: 21.9L
Fuel Type: NG/LP

Alternator:

Please refer to spec sheet for your particular model

Unit Features:

  • Heavy Duty Steel Base
  • Vibration Isolators
  • Oil Drain Valve with Extension
  • Battery Rack & Cables
  • High Ambient Unit Mounted Radiator
  • Battery Charging Alternator
  • Factory Powder Coating
  • Factory Test
  • Owner's Manual

Description:

Taylor Power standby Natural Gas (NG) / Liquid Propane (LP) generators have been ETL Certified to UL2200. Depending upon your specific requirements, Taylor Power provides standby NG/LP generators ranging from 30kW to 450kW. The TG400 is rated at 400kW and has many optional features to meet the unique needs of the individual customers. For more information on this generator, please refer to our specification sheet.

Output Power Options:

NG/LP STANDBY OUTPUT POWER OPTIONS:

LP Output Power Options NATURAL GAS
125°C RISE STANDBY RATING
LP VAPOR
125°C RISE STANDBY RATING
sKVA
Make Voltage Alternator Phase Hertz kW/kVA Amps kW/kVA Amps 30% Voltage Dip
Marathon 600 433PSL6248 3 60 400/500 482 295/369 355 1380
Marathon 277/480 433CSL6220 3 60 400/500 602 295/369 444 1469
Marathon 120/208 433CSL6220 3 60 400/500 1390 295/369 1025 1103
Marathon 120/240 433CSL6220 3 60 400/500 1204 295/369 888 1103
Marathon 120/240 433CSL6220 1 60 241/241 1004 241/241 1004 430
Stamford 277/480 HCI534C311 3 60 400/500 602 295/369 444 1480
Stamford 120/208 HCI534C311 3 60 400/500 1390 295/369 1025 1145
Stamford 120/240 HCI534C311 3 60 400/500 1204 295/369 888 1145
Stamford 120/240 HCI534C311 1 60 210/210 875 210/210 875 765
Stamford 600 HCI534D17 3 60 400/500 482 295/396 355 1520
Stamford 277/480 HCI534D311 3 60 400/500 602 300/375 452 1750
Stamford 120/208 HCI534D311 3 60 400/500 1390 300/375 1042 1390
Stamford 120/240 HCI534D311 3 60 400/500 1204 300/375 903 1390
Stamford 120/240 HCI534D311 1 60 230/230 958 230/230 958 930

NG/LP CONTINOUS OUTPUT POWER OPTIONS:

LP Output Power Options NATURAL GAS
125°C RISE CONTINOUS RATING
LP VAPOR
125°C RISE CONTINOUS RATING
sKVA
Make Voltage Alternator Phase Hertz kW/kVA Amps kW/kVA Amps 30% Voltage Dip
Marathon 600 433PSL6248 3 60 400/500 482 295/369 355 1380
Marathon 277/480 433CSL6220 3 60 400/500 602 295/369 444 1469
Marathon 120/208 433CSL6220 3 60 400/500 1390 295/369 1025 1103
Marathon 120/240 433CSL6220 3 60 400/500 1204 295/369 888 1103
Marathon 120/240 433CSL6220 1 60 241/241 1004 241/241 1004 430
Stamford 277/480 HCI534C311 3 60 400/500 602 295/369 444 1480
Stamford 120/208 HCI534C311 3 60 400/500 1390 295/369 1025 1145
Stamford 120/240 HCI534C311 3 60 400/500 1204 295/369 888 1145
Stamford 120/240 HCI534C311 1 60 210/210 875 210/210 875 765
Stamford 600 HCI534D17 3 60 400/500 482 295/396 355 1520
Stamford 277/480 HCI534D311 3 60 400/500 602 300/375 452 1750
Stamford 120/208 HCI534D311 3 60 400/500 1390 300/375 1042 1390
Stamford 120/240 HCI534D311 3 60 400/500 1204 300/375 903 1390